Validate clean.
In ten seconds.

TOUCH 3500 SYSTEM
10s
Result time
per test
50G
Onboard storage,
10M+ records
Applies to: Touch 3500 system, all CleanTrust swabs
MAGNISWAB ONLY
0.1 fmol
Detection limit
with MagniSwab
Sensitivity vs.
standard ATP swabs
Applies to: MagniSwab only

CleanTrust Swabs: Understanding the Difference

Choose the right swab for your validation needs

Swab Type
LOD
(fmol)
Certification
Application
CleanTrust
Surface Swab
Standard Sensitivity
1
Routine surface validation in regulated environments
MagniSwab
High Sensitivity
0.1
Not
Certified
Enhanced contamination detection; research and specialized applications

Built to fit the workflow you already run.

Dimensions (L × W × H)
190 × 82 × 34 mm
Weight
400 g
Display
5.5″ capacitive touchscreen
Precision
1 × 10⁻¹⁶ mol ATP
Default threshold
20–60 RLU
Test range
0–32,000 RLU/s
Test time
10 seconds
Applicable swab
17 cm swab
Battery
3.7V 3500mAh rechargeable Li-ion
Data transmission
WiFi · Bluetooth · USB-C
Storage
50G – 10M+ records

Sample to Result – simple Testing Process

1
Take out the swab

Take out the swab from the tube and rotate perpendicular to room temperature.

2
Remove swab from tube

Take out the swab from the tube.

3
Zigzag sampling

Zigzag the sampling area.

4
Put swab into tube

Put the swab into the tube.

5
Break swab tip

Break the tip to release reagent into the sample tube.

6
Shake sample

Shake well.

7
Insert swab into detector

Insert the swab into the detector.

8
Close test chamber

Close the test chamber tightly and begin testing.

CleanTrust Touch 3500 certified system

Four swabs, one luminometer.

Every CleanTrust swab shares the same 17cm format and has been validated to perform consistently across the Touch 3500, ENSURE®, ENSURE® Touch and SystemSure Plus – so switching consumables never means switching instruments or retraining staff.

CleanTrust Surf Swab
AOAC Certified

Surface Swabs

AOAC certified. The CleanTrust Surface ATP Swab, used with the CleanTrust Touch 3500, is certified for performance testing and validated for consistent results.

CleanTrust MagniSwab
High Sensitivity

MagniSwab

High sensitivity MagniSwab detects down to 0.1 fmol – designed for applications where increased sensitivity is required.

CleanTrust Water Free
Water Free

CleanTrust Water Free

Water-free formulation designed for applications where a low-volume reagent and consistent sampling performance are required.

CleanTrust Water Free Field Ready
Water Free

CleanTrust Water Free

Water-free formulation for sampling points where rapid reagent performance and field-ready testing are required.

The data behind the certification.

AOAC certification applies to the CleanTrust Touch 3500 + CleanTrust Surface ATP Swab configuration only. CleanTrust swabs are also validated to run on ENSURE®, ENSURE® Touch and SystemSure Plus – so you can switch consumables without changing instruments, SOPs, software, or staff training – but certification itself is specific to the Touch 3500.

Cross-platform compatibility data 95.4% CleanTrust results compared with ENSURE Touch
AOAC certified configuration results 96.9% CleanTrust results compared with certified configuration
Performance result 103.7% CleanTrust ATP performance comparison
MagniSwab – RLU response vs known ATP level (pure analyte) R² = 0.99
1200 1000 800 600 400 200 0
0 0.1 1 10 50 100
ATP Level (fmol)

Switch consumables, not your programme.

The certified configuration covers CleanTrust Touch 3500 + CleanTrust Surface ATP Swab. CleanTrust swabs are also validated on ENSURE®, ENSURE® Touch and SystemSure Plus.

  • Existing luminometers
  • Standard operating procedures
  • Software systems
  • Staff training procedures

Lower running costs, same validated performance.

Switching to CleanTrust can help reduce consumable costs while maintaining validated performance and familiar workflows.

  • Reduced consumable spend
  • Improved workflow efficiency
  • Validated performance

Alternative options for a quick
visual read.

When ATP isn’t needed, protein residue tests offer a fast visual alternative for quick checks.

If it’s green, it’s clean.

Surface Protein Allergen Test Swab

Detects protein residues, including potentially allergenic proteins, on cleaned surfaces.

X XXX
Pass Caution Fail High
Sensitivity 5 µg
Incubation 15 min @ 37°C
High sensitivity – detects low levels of protein residue and potentially allergenic proteins.

Surface Protein Test Swab

A ready-to-use swab for general protein residue detection on cleaned surfaces – quick and stable results in 1–10 minutes.

X X
Pass Fail Fail High
Sensitivity 80 µg
Incubation After 1 min
Rapid & reliable – clear visual results in 1–10 minutes.

Ready to see it on your own surfaces?