Qlip Dairy Reference Materials Calibration & Control
Improve raw material effiiciency with the most accurate calibration and control samples for your dairy testing instruments – Provided by Europe’s largest milk testing laboratory.
How Qlip Assures Accuracy
With our 15 Million raw milk samples tested anually, Qlip is Europe’s largest milk testing laboratory. Our ISO 17025 accreditation and rigorous quality standard ensure unmatched reliability.
Quality Assurance Standards
Rose Gottlieb & Kjeldahi Analyses
200,000+
Performed anually with 90% carried out in duplicate
Uncertainty of Measurement
0.01%
For both fat and protein – industry-leading precision
The Impact of Accuracy Improvement
With our 15 Million raw milk samples tested anually, Qlip is Europe’s largest milk testing laboratory. Our ISO 17025 accreditation and rigorous quality standard ensure unmatched reliability.
Example Calculation
Annual Savings
Protein Savings
£2,25,000
Monthly: £18,750
Fat Savings
£1,12,500
Monthly: £9,375
Lactose Savings
£25,000
Monthly: £1,875
Complete Calibration & Control Portfolio
Browse our full range of ISO 17025 accredited reference materials. Click any category to expand the product list and access our webshop.
Raw Milk Calibration Samples
Calibration sets for raw milk analysers — fat, protein, lactose & more
| Product | Type | Parameters | Action |
|---|---|---|---|
| MCS7 Extended fat range only | Calibration |
Fat 0–6% Extended fat range only – fatty acids (FA) not included |
Get Quote |
| MCS17 Full component set | Calibration |
Fat 0–6% · Protein 1.7–5.3% · Lactose 3–6% + TS cert • + AC cert • + NC cert Optional certificates for Total Solids, Artificial Casein & Natural Casein available |
Get Quote |
| MCS17-P6 Extended protein range | Calibration |
Fat 0–6% · Protein 1.7–8% · Lactose 3–6% Extension of MCS17 – extends protein range up to 8% |
Get Quote |
| FFD8 Freezing point . 8 samples X 2 | Calibration |
Freezing Point Depression (FPD) 8 – sample calibration set supplied as a duplicate (two identical sets). Used to calibrate FPD to determine added water in raw milk. |
Get Quote |
Raw Milk Control Samples
Daily monitoring of analyser performance — verify against known values
| Product | Type | Parameters | Action |
|---|---|---|---|
| Raw Milk Control Individual sample | Control |
Fat · Lactose Daily use – confirm available levels from order form. Comprehensive parameter data available; certificate to be shared separately. |
Get Quote |
| RMP-30 34-sample set | Control |
Fat · Protein · Lactose · TS · FPD 34 raw milk samples with comprehensive test data. Available as individual supply or as a monthly set of 34 samples. |
Get Quote |
Processed Milks Control Samples
Control samples for homogenised & processed milk analysers
| Product | Type | Parameters | Action |
|---|---|---|---|
| Homogenised Milk Control Processed milk | Control |
Fat · Protein · Lactose · Total Solids · Urea · NPN · Casein · FPD Homogenised (processed) milk control. |
Get Quote |
Waterbath Control & Calibration Sample Rack
To complement our popular Calibration & Control Samples, LABTEK Services Ltd now offers a customised Waterbath Sample Rack to assist correct warming of the sample.
Sample Preparation Guidelines
Temperature Control
Preheat samples to 40 ±2°C for no more than 15 minutes for Milk/Whey Samples. Additional 5 minutes may be required for Cream Samples.
Water Level
Ensure the water level of the Waterbath covers the whole sample.
Sample Mixing
Mix the sample thoroughly by inversion ensuring all solidified fat is in suspension and no fat is adhering to the side or top of the container. Do not shake!
Visual Inspection
Do not use samples which have separated or oiled off.
Storage
Samples may be kept at room temperature until tested, provided they are tested within 30 minutes after reaching 40 ±2°C. Remix thoroughly before testing.
Why Choose Qlip Calibration Materials?
Proven Reliability
Trusted by Europe’s largest milk testing laboratory with over 15 million samples tested anually. Our materials have been validated through rigorous testing protocols.
Lowest Uncertainty
Uncertainty of Measurement of 0.01% for fat and protein, achieved through over 2,00,000 annual reference analyses performed in duplicate.
Customisation Available
We offer customised versions of both calibration samples and waterbath racks to meet your specific testing requirements and laboratory setup.
ISO 17025 / ISO 17034 Accreditation
Our laboratory follows internationally recognized ISO standards, ensuring the highest quality standards for all calibration and control samples.
Wide Component Ranges
Raw Milk Calibration Samples with 6% and 5% protein and lactose ranges ensure robust and reliable calibration lines for your instruments.
Significant Cost Savings
Even 0.01% accuracy improvement can save dairy processors thousands annually. Invest in precision, gain substantial ROI.
Get in Touch
Contact LABTEK Services Ltd to discuss your calibration and control sample requirements.
Address
108 Preston Grove Yeovil Somerset BA20 2DA United Kingdom
Contact Details
Tel: 00 44 193473824
Email: sales@labtekservices.co.uk
Website
www.labtekservices.co.uk
ISO 9001:2015 Certified Company
Control Sample Document
Download our QLIP control sample document, which provides further details of the extensive range available for monitoring your FTIR/NIR Analyser using QLIP reference materials.
Sample Preparation Protocol
Full protocol covering waterbath settings (40-42 C), homogenisation requirements, visual inspection criteria, and storage guidance. Scan the QR code in the Products Section for instant mobile access.
